<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-31 21-56-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 61 dBuV SANDELS
Pilot RDS Phase Difference
6.2 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 16 kHz 12363 8,6872
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,5 dBr 3,96 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 16 kHz MIN: 11 kHz % above 76 kHz: 8,6872 Acquired: 2024/12/31 21.55.42 Total samples: 12363 Equivalent time: 0:10:18 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 6,2 dBr MIN: 1,5 dBr AVE: 3,96 dBr % above 12,2 dBr: 0,0 Last value: 2,6 dBr (2024/12/31 21.55.42) 21.42 21.44 21.46 21.48 21.50 21.52 21.54 0 2 4 6 Pm [dBr]